Sign In | Join Free | My insurersguide.com
China Guangzhou Xinlin Fire Fighting Equipment Co., Ltd. logo
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
Provide first-class fire products and services. Create a safer space for customers and create greater value for customers.
Verified Supplier

2 Years

Home > FM200 Gas Suppression System >

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

  • 1
  • 2

Brand Name : xinlin

Model Number : QMQ5.6/90N-XL-004

Certification : UL,FM,CMA,CNAS

Place of Origin : China

MOQ : 1

Price : negotiation

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 20000 sets per week

Delivery Time : 10-15 working days after payment or receipt of L/C

Packaging Details : Plywood outer box with bubble bag or paper

Maximum working pressure : 8MPA(20°C)

Filling Density : ≤1080kg/m3

Name : Fm200 System

System Blowdown Time : Computer Room ≤8s, Other ≤10s

Starting Mode : Automatic, Electrical Manual, Mechanical Emergency

Storage pressure : 5.6MPA(20°C)

Scope of work : 0°C~50°C

Fire extinguishing design concentration : 8~10℃

Contact Now

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

Product Description:

Heptafluoropropane (HFC-227ea/FM-200) is a colorless, odorless, non-conductive, and no

secondary pollution gas with clean, low toxicity, good electrical insulation, high fire-extinguishing efficiency, particularly its non-ozone destruction , the residence time in the atmosphere is relatively short, its environmental performance is superior to Halon, is by far the more successful research and development of a clean gas extinguishing agent, can be used safely in the workplace has staff also replace Halon's most 1301,1211 one of the ideal product.

Technical Parameters:

Product Name FM200 System
Filling pressure 4.2 MPa
Starting Mode Automatic, Electrical Manual, Mechanical Emergency
System Power Supply AC220V/DC24V/1A
Filling Density ≤1080kg/m3
Scope of Work 0°C~50°C
Storage bottle volume 90L, 120L,150L, 180L
System Blowdown Time Computer Room ≤8s, Other ≤10s
Maximum Working Pressure 5.3MPA(+20°C)



Applications:


Automatic suppression systems based on the FM200 are used in critical areas of significant strategic value. Critical areas are those that house high-cost investment elements and/or are fundamental to the operation of a company or even society.

The FM200 gas system is widely used to protect:

· Process control rooms in refineries, gas plants, power plants, petrochemical plants, etc.

· Substations at power distribution companies and refineries

· Substations at train and subway stations

· Railway signal rooms

· Electrical rooms or distribution rooms

· Server rooms

· Telecommunications rooms or communication centers for internet service providers and mobile phone operators

· Motor control centers (MCCs) in industry and other sectors

· Data centers for banks, oil companies, mining companies, etc.

· Permanent Gas (PTG) gas and Permanent Petroleum (PTC) oil processing facilities

· Offshore platform facilities

· Zoned distribution rooms

· Airport control rooms


Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage



Maintenance requirement


Check the system regularly, including the pressure check of the fire extinguishing agent bottle group, generally check the bottle group pressure at least once a month to ensure that the pressure is within the specified range. Check pipes and fittings for leakage, and use soapy water and other methods to detect leakage. It is also necessary to perform functional tests on the electrical components of the system, such as fire detectors, controllers, etc., to ensure that the system can start and operate normally. In addition, every five years should be a comprehensive test of the system, including fire extinguishing agent quality testing.


Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

Why choose us:


• Efficient management system

• More than 10 years of experience in gas fire fighting industry

• Advanced equipment and professional engineers

• We provide 8×6 hr technical support and after-sales service


Frequently Asked Questions

-----------------------------------------------------------------------------------

Q1Are you a manufacturer or a trading company?

A1: We are the manufacturer.


Q2: Do you have OEM orders?

A2: Yes, according to the customer's requirements.


Q3: Where is your factory located? How do I get there?

A3: Our factory is located in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.

You are very welcome to visit our factory.



Product Tags:

Automatic FM200 fire suppression system

      

Large area gas suppression system

      

Internal storage pressure fire system

      
Cheap Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage for sale

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)